Region-wise evaluation of price-based demand response programs in Japan's wholesale electricity market considering

Ladan Malehmirchegini1, Mohamed Saad Suliman1, Hooman Farzaneh1,2

  • 1Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka, Japan.

Iscience
|June 19, 2023
PubMed

Related Concept Videos

Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
140
Potential-Energy Criterion for Equilibrium01:16

Potential-Energy Criterion for Equilibrium

Potential energy or potential function plays an essential role in determining the stability of a mechanical system. If a system is subjected to both gravitational and elastic forces, the potential function of the system can be expressed as the algebraic sum of gravitational and elastic potential energy. If the system is in equilibrium and is displaced by a small amount, then the work done on the system equals the negative of the change in the system's potential energy from the initial to...
585
Alternative Sets of Equilibrium Equations01:31

Alternative Sets of Equilibrium Equations

When analyzing the behavior of structures, engineers often rely on the concept of equilibrium. This refers to the state where all forces and moments acting on a system balance each other, resulting in no net movement or rotation. In many cases, equilibrium can be described by a set of standard equations. However, in some situations, alternative sets of equilibrium equations must be used to describe the system's behavior accurately.
One example of such a situation can be observed in a...
424
Dynamic Equilibrium02:20

Dynamic Equilibrium

A reversible chemical reaction represents a chemical process that proceeds in both forward (left to right) and reverse (right to left) directions. When the rates of the forward and reverse reactions are equal, the concentrations of the reactant and product species remain constant over time and the system is at equilibrium. A special double arrow is used to emphasize the reversible nature of the reaction. The relative concentrations of reactants and products in equilibrium systems vary greatly;...
52.0K
The Power Flow Problem and Solution01:26

The Power Flow Problem and Solution

Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk​, phase angle δk​, real power Pk​, and reactive power Qk​. Two of these four variables are inputs, while the...
270
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model01:13

Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model

Drugs administered through various routes can lead to nonlinear elimination, resulting in complex pharmacokinetic behaviors crucial to understanding efficacious drug dosing.
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
98