Influence of Torque on Platform Deformity of the Tri-Channel Implant: Two- and Three-Dimensional Analysis Using
Renata Costa de Morais1, Anselmo Agostinho Simionato1, Izabela Cristina Maurício Moris2
1Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-904, Brazil.
Abstract:
Background and Objectives: The insertion of the dental implant in the bone is an essential step in prosthetic rehabilitation. The insertion torque has the potential to distort the prosthetic platform, which can cause future biomechanical problems with the continuous action of occlusal forces. The aim of this study is to evaluate different insertion torques in the deformation of tri-channel platform connections through two- and three-dimensional measurements with micro-CT. Materials and Methods: A total of 164 implants were divided into groups (platform diameter and type): 3.5, 3.75, and 4.3 mm NP (narrow platform), and 4.3 mm RP (regular platform). Each implant-platform group was then divided into four subgroups (n = 10) with different torques: T45 (45 Ncm), T80 (80 Ncm), T120 (120 Ncm), and T150 (150 Ncm). The implant-abutment-screw assemblies were scanned and the images obtained were analyzed. Results: A significant difference was observed for the linear and volume measures between the different platforms (p < 0.01) and the different implant insertion torques (p < 0.01). Qualitative analysis suggested a higher deformation resistance for the 3.75 NP compared to the 3.5 NP, and RP was more resistant compared to the NP. Conclusions: The 0.25 mm increment in the implant platform did not increase the resistance to the applied insertion torques; the 4.3 mm implant was significantly stronger compared to the 3.5 mm implant; and the proposed micro-CT analysis was considered valid for both the 2D and 3D analyses of micro-gaps, qualitatively and quantitatively.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Deformation in a Circular Shaft
Plastic Deformation in Circular Shafts
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Normal Strain under Axial Loading