Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
Point-of-care detection devices for wound care and monitoring
Shu-Wei Huang1, Yu-Feng Wu2, Tanvir Ahmed3
1Department of Orthopedic Surgery, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan.
Abstract:
Healthcare resources are heavily burdened by infections that impede the wound-healing process. A wide range of advanced technologies have been developed for detecting and quantifying infection biomarkers. Finding a timely, accurate, non-invasive diagnostic alternative that does not require a high level of training is a critical step toward arresting common clinical patterns of wound health decline. There is growing interest in the development of innovative diagnostics utilizing a variety of emerging technologies, and new biomarkers have been investigated as potential indicators of wound infection. In this review, we summarize diagnostics available for wound infection, including those used in clinics and still under development.
More Related Videos
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
04:58Collecting And Measuring Wound Exudate Biochemical Mediators In Surgical Wounds
Published on: October 20, 2012
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Peripheral Artery Disease V: Postoperative Nursing Management