Related Experiment Video
Updated: Jul 17, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
A novel adaptive droop control strategy for SoC balance in PV-based DC microgrids
Boxi Li1, Chang Yu2, Xiaoqing Lu3
1Hubei Collaborative Innovation Center for High-efficiency Utilization of Solar Energy, Hubei University of Technology, Wuhan 430068, PR China.
None:
Battery energy storage systems (BESSs) are generally used as a buffer stage for photovoltaic (PV) power generation to tolerate the output power unpredictability in DC microgrids, in which the State-of-Charge (SoC) balance is a necessary and urgent issue to be solved. To this end, an integral feedforward sliding mode controller (SMC) is adopted to replace the traditionally proportional integral (PI) controller such that the voltage response speed of the converter in each BESS can be significantly enhanced. Further, a novel adaptive droop control strategy for SoC balance with three different working modes is proposed, in which all batteries can be cooperated through three different stages corresponding to their different SoC degrees. Compared with most existing SoC balancing approaches, the proposed SoC strategy can improve the transient performance for the BESSs and their robustness against the volatility of PV output powers. The effectiveness of the proposed SoC balancing strategy is verified through a simulation in a DC microgrid network consisting of several PV generators, batteries, and loads utilizing Simulink/SimPower Systems.
More Related Videos
11:06A Human-machine-interface Integrating Low-cost Sensors with a Neuromuscular Electrical Stimulation System for Post-stroke Balance Rehabilitation
Published on: April 12, 2016
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
Related Concept Videos
Fast Decoupled and DC Powerflow
Load-frequency control
Control of Power Flow
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...