Evaluation of stroke volume estimation during orthostatic stress: the utility of Modelflow
Vera-Ellen M Lucci1, Iain T Parsons2,3, Brooke C D Hockin1
1Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, Canada.
Abstract:
Advanced blood pressure monitoring devices contain algorithms that permit estimation of stroke volume (SV). Modelflow (Finapres Medical Systems) is one common method to non-invasively estimate beat-to-beat SV. However, Modelflow accuracy during profound reductions in SV is unclear. We aimed to compare SV estimation by Modelflow and echocardiography, at rest and during orthostatic challenge. We tested 13 individuals (age 24 ± 2 years; 7 female) using combined head-up tilt and graded lower body negative pressure, continued until presyncope. SV was derived by both Modelflow and echocardiography on multiple occasions while supine, during orthostatic stress, and at presyncope. SV index (SVI) was determined by normalising SV for body surface area. Bias and limits of agreement were determined using Bland-Altman analyses. Two one-sided tests (TOST) examined equivalency. Across all timepoints, Modelflow estimates of SV (73.2 ± 1.6 ml) were strongly correlated with echocardiography estimates (66.1 ± 1.3 ml) (r = 0.56, P < 0.001) with a bias of +7.1 ± 21.1 ml. Bias across all timepoints was further improved when SV was indexed (+3.6 ± 12.0 ml.m -2 ). Likewise, when assessing responses relative to baseline, Modelflow estimates of SV (-23.4 ± 1.4%) were strongly correlated with echocardiography estimates (-19.2 ± 1.3%) (r = 0.76, P < 0.001), with minimal bias (-4.2 ± 13.1%). TOST testing revealed equivalency to within 15% of the clinical standard for SV and SVI, both expressed as absolute values and relative to baseline. Modelflow can be used to track changes in SV during profound orthostatic stress, with accuracy enhanced with correction relative to baseline values or body size. These data support the use of Modelflow estimates of SV for autonomic function testing.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...