Comparison of Rapid Antigen Detection Test with Reverse Transcription Polymerase Chain Reaction in Highly Suspected
Muhammad Abdur Rahman Afridi1, Zafar Ali1, Naveed Iqbal1
1Department of Medicine, Lady Reading Hospital, Medical Teaching Institution, Peshawar, Pakistan.
Objective:
To compare Rapid Antigen Test (RAT) with Reverse Transcription Polymerase Chain Reaction (RT-PCR) in highly suspected COVID-19 patients and to determine its diagnostic parameters.
Study Design:
Hospital-based, descriptive/observational study. Place and Duration of the Study: Department of Medicine/COVID Complex, Medical Teaching Institution/Lady Reading Hospital, Peshawar, Khyber Pakhtunkhwa, Pakistan, from October 2021 to April 2022.
Methodology:
A total of 300 highly suspected cases of COVID-19 of either gender admitted in the COVID Complex of the hospital, were included. Data from the patients, including RAT and RT-PCR for COVID-19, were collected retrospectively. RT-PCR was used as the reference test and compared with RAT. Diagnostic statistics of RAT, with their respective 95% confidence intervals were calculated for RAT in diagnosing COVID-19, with significance at p ≤0.05.
Results:
Among the 300 patients, 137 (45.7%) were males and 163 (54.3%) were females. The mean age was 56.80 ± 13.72 years. On screening, 138 (46%) patients tested positive and 162 (54%) were negative by RAT; whereas 213 (71%) tested positive and 87 (29%) were negative on RT-PCR. The sensitivity and specificity of RAT were 54.5% (95% CI: 47.52%-61.28%) and 74.7% (95% CI: 64.25%-83.42%), respectively. Positive predicted value was 84.1% (95% CI: 78.26%-88.53%) and negative predictive value was 40.1% (95% CI: 35.63%-44.79%). The positive likelihood ratio was 2.15 (95% CI: 1.47-3.15). The negative likelihood-ratio was 0.61(95% CI: 0.50-0.74). The overall accuracy was 60.33% (95% CI: 54.55%-65.91%).
Conclusion:
There was a low sensitivity and specificity of the RAT for COVID-19, with an overall accuracy of 60.33%, compared with RT-PCR.
Key Words:
COVID-19, Rapid Antigen Test, Sensitivity, Specificity, RT-PCR.