Related Experiment Video
Updated: Jul 15, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Active Fault-Tolerant and Attack-Resilient Control for a Renewable Microgrid Against Power-Loss Faults and Data
Abstract:
The next-generation power grid evolves from the development of fundamental cyber-physical energy systems called smart microgrids. In order to improve the reliability, safety, and security of smart microgrids and achieve a more cost-effective operation, innovative approaches for physical fault diagnosis and fault-tolerant control (FTC) as well as intrusion detection and attack-resilient control (ARC) should be investigated. Given that, this article considers a smart hybrid renewable-based microgrid with different types of distributed generation units, including solar photovoltaic (PV) array, wind turbines, and battery energy storage system. Novel active FTC and ARC strategies are designed for pulse-width modulation (PWM) converters at microgrid level. The proposed fault-tolerant controller is based on an optimal fuzzy gain-scheduling technique that is used to accommodate the adverse impacts of PV power-loss faults. Also, the proposed attack-resilient controller relies on the estimated values of sensor measurements during the occurrence of data integrity cyber-attacks. To access and evaluate the microgrid's real-time health status, both FTC and ARC strategies employ an integrated model-based intrusion detection and fault diagnosis (IDFD) system that is designed using a fuzzy modeling and identification technique. Finally, the effectiveness of the proposed solutions is demonstrated via a series of simulations in MATLAB/Simulink using an advanced microgrid benchmark.
More Related Videos
09:19In Situ Monitoring of the Accelerated Performance Degradation of Solar Cells and Modules: A Case Study for CuIn,GaSe2 Solar Cells
Published on: October 3, 2018
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
Related Concept Videos
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Distribution Reliability and Automation
Power System Three-Phase Short Circuits
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Line Protection with Impedance Relays