Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
Portable dual-channel blood enzyme analyzer for point-of-care liver function detection
Jingwei Sang1, Jie Cheng2, Honghua Hu3
1University of Electronic Science and Technology of China, Chengdu 611731, China.
Abstract:
Because the liver is an important metabolic center in the human body, the reliability and timeliness of chronic liver disease diagnosis are particularly important. Alanine aminotransferase and aspartate transaminase are the two most important liver function indicators, and their test results are crucial in the diagnosis of liver diseases. However, the simultaneous detection of these two indicators is currently restricted by the need for expensive equipment and complicated detection processes. This study proposes a portable dual-channel blood enzyme analyzer (BEA) for point-of-care-testing. The device uses photometric reflectance to quantify the enzyme concentration by evaluating the reflected light intensity. The BEA also precisely controls and maintains the temperature at 37 °C ± 0.1 °C in the dual-channel assay. We assessed the responses of this system within a clinically relevant range by testing blood samples from a local hospital. The test verified that BEA for ALT and AST achieved a detection limit of 3.5 U L-1 and 4 U L-1, detection range of 4-350 U L-1 and 4-250 U L-1, coefficients of variation (CV) that were both less than 10%, and a linear correlation coefficient of 0.9827 and 0.9714 compared with a high-precision clinical biochemistry analyzer (Roche Cobas C702), respectively. We realized remote data analysis and storage through connection with smartphones, which can be applied to remote diagnostics and preventative personal disease management. Therefore, BEA has broad application prospects in the future internet of medical things.
More Related Videos
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
11:06Human Liver Microphysiological System for Assessing Drug-Induced Liver Toxicity In Vitro
Published on: January 31, 2022
Related Concept Videos
Enzyme-linked Receptors
Neurotrophin (NT) receptors are a family of RTKs, including trkA, trkB, and trkC (tropomyosin-related kinase) receptors. TrkA is specific for nerve growth factor (NGF), neurotrophin-6, and neurotrophin-7. TrkB binds...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...