Rational Atom Substitution to Obtain Efficient, Lead-Free Photocatalytic Perovskites Assisted by Machine Learning and

Xuying Li1, Haoxin Mai1, Junlin Lu2

  • 1Applied Chemistry and Environmental Science, School of Science, STEM College, RMIT University, Melbourne, Victoria 3000, Australia.

Related Concept Videos

Nuclear Transmutation03:20

Nuclear Transmutation

Nuclear transmutation is the conversion of one nuclide into another. It can occur by the radioactive decay of a nucleus, or the reaction of a nucleus with another particle. The first manmade nucleus was produced in Ernest Rutherford’s laboratory in 1919 by a transmutation reaction, the bombardment of one type of nuclei with other nuclei or with neutrons. Rutherford bombarded nitrogen-14 atoms with high-speed α particles from a natural radioactive isotope of radium and observed protons being...
Nuclear Overhauser Enhancement (NOE)01:06

Nuclear Overhauser Enhancement (NOE)

Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the nuclear Overhauser enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring spin-active...
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Fluorescence Spectroscopy01:29

Atomic Fluorescence Spectroscopy

Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which are...