Related Experiment Video
Updated: Aug 6, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Percutaneous Management of Aortic Root Rupture After Balloon-Expandable TAVR
Domingo Lopez Vazquez1, Xacobe Flores Rios1, Jorge Salgado Fernandez1
1Cardiology, Complexo Hospitalario Universitario A Coruña (CHUAC), SERGAS, A Coruña, Spain.
Abstract:
This article presents a case of aortic root rupture after transfemoral aortic valve replacement, successfully treated by a percutaneous approach, with a good evolution of the patient both during hospitalization and in the long term, being asymptomatic at the cardiovascular level after 18 months of follow-up. (Level of Difficulty: Advanced.).
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aneurysm III: Interprofessional Care
Aneurysm IV: Nursing Management