Comparison of Blue and Infrared Light Transmission Through Dental Tissues and Restorative Materials
R R Pacheco1, A F Garcia-Flores2, G G Lesseux3
1*Rafael Rocha Pacheco, DDS, MSc, PhD, Department of Restorative Sciences, The Dental College of Georgia at Augusta University, Augusta, GA, USA.
Objectives:
The depth of cure using blue-light photocuring units (BL) is limited by tooth structure and qualities of the restorative material through which the activating wavelength must pass. Recent developments incorporate an infrared (IR) activated upconversion (UC) fluorescence of a lining agent filled with nanocrystals of NaYF4 and doped with YB+3 and Tm+3 that emit both blue and violet light locally at the interface of the liner and restorative resin. The purpose of this study was to evaluate the BL and 975 nm infrared (IR) light power transmission through dental tissues and restorative materials.
Methods And Materials:
Power transmissions of the IR laser (975 nm) and a monowave blue-only light-curing unit (Bluephase 16i) through dental tissues (enamel, dentin, and enamel/dentin junction, or DEJ), eight (8) various dental resin composites, and eight (8) dental ceramics, each at four thicknesses (1, 2, 3 and 4 mm) were evaluated (n=5) using a thermopile sensor (PM10, Coherent Inc) connected to a laser power meter (Fieldmate, Coherent Inc). Power transmission values of each light source and restorative material were subjected to analysis of variance and Tukey test at a pre-set alpha of 0.05.
Results:
A linear correlation (r=0.9884) between the supplied current and emitted IR power of the laser diode was found, showing no statistical power reduction with increased distances (collimated beam). For tooth tissues, the highest power transmissions for both light sources were observed using 1.0 mm enamel while the lowest values were found for 2.0 mm dentin and an association of 2.0 mm DEJ and 1.0 mm dentin. The only group where IR demonstrated significantly higher transmission when compared to BL was 1.0 mm enamel. For all resin composites and dental ceramics, increased thickness resulted in a reduction of IR power transmission (except for EverX Posterior fiber-reinforced composite and e.max HT ceramic). IR resulted in higher transmission through all resin composites, except for Tetric EvoCeram White. The highest BL transmission was observed for SDR Flow, at all thicknesses. Higher IR/BL ratios were observed for EverX Posterior, Herculite Ultra, and Lava Ultimate, while the lowest ratio was observed for Tetric EvoCeram White. Reduced translucency shades within the same material resulted in lower power ratio values, especially for BL transmission. Higher IR/BL ratios were observed for e.Max LT, VitaVM7 Base Dentin, and e.max CAD HT, while the lowest values were found for VitaVM7 Enamel and Paradigm C.
Conclusion:
IR power transmission through enamel was higher when compared to blue light, while no difference was observed for dentin. The power transmission of IR was higher than BL for resin composites, except for a high value and low chroma shade. Fiber-reinforced resin composite demonstrated the highest IR/BL power transmission ratio. A greater IR/BL ratio was observed for lower translucency ceramics when compared to high translucency.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
X-ray Imaging
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...