Related Experiment Video
Updated: Jun 28, 2025

Automated Sample Multiplexing by using Combined Precursor Isotopic Labeling and Isobaric Tagging cPILOT
Published on: December 18, 2020
Pushing the Isotopic Envelope: When carrier channels pollute their neighbors' signals
Connor Peterson1, Hannah Boekweg1, Eilenora Presley1
1Biology Department, Brigham Young University, Provo UT 84604.
Abstract:
Individual cells are the foundational unit of biology, and understanding their functions and interactions is critical to advancing our understanding of health and disease. Single cell proteomics has seen intense interest from mass spectrometrists, with a goal of quantifying the proteome of single cells by adapting current techniques used in bulk samples. To date, most method optimizations research has worked towards increasing the proteome coverage of single cells. One prominent technique multiplexes many individual cells into a single data acquisition event using isobaric labels. Accompanying the single cells, one label is typically used for a mixed set of many cells, called a carrier or boost channel. Although this improves peptide identification rates, several groups have examined the impact on quantitative accuracy as more cells are included in the carrier channel, e.g. 100x or 500x. This manuscript explores how impurities in the multiplexing reagent can lead to inaccurate quantification observed as a measurable signal in the wrong channel. We discover that the severe abundance differential between carrier and single cell, combined with the reagent impurities, can overshadow several channels typically used for single cells. For carrier amounts 100x and above, this contamination can be as abundant as true signal from a single cell. Therefore, we suggest limiting the carrier channel to a minimal amount and balance the goals of identification and quantification.
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Mass Spectrometry: Isotope Effect
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...

