Related Experiment Video
Updated: Jun 25, 2025

Biochemical Measurement of Neonatal Hypoxia
Published on: August 24, 2011
Rapid and reliable quantification of urinary malondialdehyde by HILIC-MS/MS: A derivatization-free breakthrough
Gabriela Chango1, Diego García-Gómez1, Carmelo García Pinto1
1Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, Universidad de Salamanca, 37008, Salamanca, Spain.
Background:
The development of fast analytical methods is crucial for the research, discovery, and confirmation of crucial biomarkers. Furthermore, the implementation of fast analytical strategies contributes to efficient and time-effective procedures. In this sense, analysis of malondialdehyde (MDA) has become an important tool for understanding the role of oxidative stress in various diseases and for evaluating the efficacy of therapeutic interventions.
Results:
A rapid and robust liquid chromatography tandem mass spectrometry method (HPLC-MS/MS) has been developed to determine endogenous amounts of malondialdehyde (MDA) in human urine without any associated derivatization reaction. MDA was separated in 4 min through a Urea-HILIC column and was analyzed using a triple quadrupole mass spectrometer in negative electrospray ionization mode. With a 50-fold dilution as the only sample pretreatment after alkaline hydrolysis, no matrix effect was present, which allowed for a fast and simple quantification by means of an external standard calibration with a limit of detection of 0.20 ng mL-1. The whole methodology was validated by analyzing unspiked and spiked urine samples from ten healthy individuals and comparing with the results obtained by the standard addition method. MDA was detected in all cases, with natural concentrations varying from 0.11 ± 0.03 to 0.31 ± 0.03 mg g-1 creatinine. Accuracies were found to be satisfactory, ranging from 95 % to 101 %. The proposed method also exhibited good repeatability and reproducibility (RSD<15 %) for four quality control levels.
Significance:
The main significance of this method is the avoidance of a derivatization reaction for the determination of urinary MDA, this constituting a step forward when compared with previous literature. This breakthrough not only streamlines time analysis to less than 5 min per sample but also results in a more robust procedure. Consequently, the method here developed could be applied to subsequent future research involving the determination of MDA as a lipid peroxidation biomarker, where simple, rapid, and reliable methods could represent a significant improvement.
More Related Videos
06:19Evaluation of Oxidative Stress in Biological Samples Using the Thiobarbituric Acid Reactive Substances Assay
Published on: May 12, 2020
12:15Quantification of three DNA Lesions by Mass Spectrometry and Assessment of Their Levels in Tissues of Mice Exposed to Ambient Fine Particulate Matter
Published on: May 29, 2019