Interreader and Intrareader Reproducibility of 18F-Flotufolastat Image Interpretation in Patients with Newly
Phillip H Kuo1, Giuseppe Esposito2, Gary A Ulaner3,4
1Departments of Medical Imaging, Medicine, and Biomedical Engineering, University of Arizona, Tucson, Arizona; kuoradiology@gmail.com.
Summary
Interreader and intrareader reproducibility of 18F-flotufolastat PET/CT scans was high in prostate cancer patients. These findings indicate reliable interpretation of 18F-flotufolastat PET/CT imaging for both newly diagnosed and recurrent disease.
Area of Science:
- Nuclear Medicine
- Radiology
- Oncology
Background:
- Prostate cancer diagnosis and staging rely on accurate imaging.
- 18F-flotufolastat Positron Emission Tomography/Computed Tomography (PET/CT) is an emerging imaging modality.
- Assessing the reliability of 18F-flotufolastat PET/CT interpretation is crucial for clinical adoption.
Purpose of the Study:
- To evaluate the interreader and intrareader reproducibility of 18F-flotufolastat PET/CT scan interpretations.
- To assess the reliability of image analysis in both newly diagnosed and recurrent prostate cancer patients.
Main Methods:
- Masked image evaluations of 18F-flotufolastat PET/CT scans from two Phase 3 studies involving 352 newly diagnosed and 389 recurrent prostate cancer patients.
- Three masked readers assessed images, utilizing Cohen κ for pairwise agreement and Fleiss κ for overall agreement.
- Intrareader agreement was assessed by comparing initial reads with repeat reads (20% of images) conducted at least 4 weeks later.
Main Results:
- High pairwise interreader agreement was observed: ≥95% in newly diagnosed and ≥75% in recurrent prostate cancer patients.
- Agreement was highest in the prostate for newly diagnosed patients (≥95%) and pelvic lymph nodes for recurrent patients (≥87%).
- Intrareader agreement exceeded 86% across both patient populations, indicating consistent individual interpretation.
Conclusions:
- 18F-flotufolastat PET/CT imaging demonstrates a high degree of reliability in interpretation.
- The study confirms substantial inter- and intrareader agreement, supporting its clinical utility in prostate cancer management.