Related Experiment Video
Updated: Jun 23, 2025

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Evaluation of RPLC stationary phases for tocopherol and tocotrienol positional isomer separation: Method development
Georgijs Baškirovs1, Krists Dukurs1, Arianne Soliven2
1Institute of Horticulture, Graudu 1, Dobele, LV-3701, Latvia.
Abstract:
Reversed-phase separation of tocopherols (Ts) and tocotrienols (Ts) using C18 stationary phases results in the coelution of β and γ positional isomers, leading to identification errors. This study investigates the potential of alternative stationary phase chemistries to effectively resolve tocochromanols, specifically focusing on the critical pair of β and γ positional isomers. Initial screening of seven different stationary phases (C18, C18-PFP, C30, PFP, 5PYE, πNAP, and RP-Amide) was conducted. Linear solvent strength (LSS) studies were performed to assess the impact of the organic modifier (methanol) and temperature on the chromatographic performance parameters. Five columns were found to be suitable for the tocochromanol separation and two different chromatographical conditions per column were proposed. Elution order of tocochromanols was unique for 5PYE, πNAP and C30 columns in comparison to RP-Amide and PFP. Method development for the quantitative analysis of four tocopherol and four tocotrienol homologues was performed. The optimised method employed the RP-Amide (150 × 4.6 mm, 2.6 μm dp) superficially porous particle column, mobile phase of methanol:water of 92:8, v/v, with a flow rate of 1.0 mL/min, column oven temperature of 40 °C and fluorescence detection (λex 295 nm, λem 330 nm). The analysis run time was 10.5 min with 13.6 MPa back pressure. The method was validated and the obtained LOQs were found to be 1.30-3.13 μg/mL. The method developed was successfully applied for the determination of tocochromanols in twenty samples with unique tocochromanol profiles. Principal component analysis illustrated three distinct groups based on the tocochromanol profile.
Related Concept Videos
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...