Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Enhancing Coordination Efficiency with Fuzzy Monte Carlo Uncertainty Analysis for Dual-Setting Directional
Faraj Al-Bhadely1, Aslan İnan1
1Department of Electrical Engineering, Yildiz Technical University, Istanbul 34220, Turkey.
Abstract:
In the contemporary context of power network protection, acknowledging uncertainties in safeguarding recent power networks integrated with distributed generation (DG) is imperative to uphold the dependability, security, and efficiency of the grid amid the escalating integration of renewable energy sources and evolving operational conditions. This study delves into the optimization of relay settings within distribution networks, presenting a novel approach aimed at augmenting coordination while accounting for the dynamic presence of DG resources and the uncertainties inherent in their generation outputs and load consumption-factors previously overlooked in existing research. Departing from conventional methodologies, the study proposes a dual-setting characteristic for directional overcurrent relays (DOCRs). Initially, a meticulous modeling of a power network featuring distributed generation is undertaken, integrating Weibull probability functions for each resource to capture their probabilistic behavior. Subsequently, the second stage employs the fuzzy Monte Carlo method to address generation and consumption uncertainties. The optimization conundrum is addressed using the ant lion optimizer (ALO) algorithm in the MATLAB environment. This thorough analysis was conducted on IEEE 14-bus and IEEE 30-bus power distribution systems, showcasing a notable reduction in the total DOCR operating time compared to conventional characteristics. The proposed characteristic not only achieves resilient coordination across a spectrum of uncertainties in both distributed generation outputs and load consumption, but also strengthens the resilience of distribution networks overall.
Related Concept Videos
Directional Relays
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Distribution Reliability and Automation
Distributed Loads: Problem Solving