Assessment of image quality and establishment of local acceptable quality dose for computed tomography based on
Nada Hasan1,2, Chadia Rizk3, Fatema Marzooq2
1University of Bahrain, Environment and Sustainable Development Program, College of Science, Zallaq, Kingdom of Bahrain.
Purpose:
We aim to develop modified clinical indication (CI)-based image quality scoring criteria (IQSC) for assessing image quality (IQ) and establishing acceptable quality doses (AQDs) in adult computed tomography (CT) examinations, based on CIs and patient sizes.
Approach:
CT images, volume CT dose index ( ), and dose length product (DLP) were collected retrospectively between September 2020 and September 2021 for eight common CIs from two CT scanners at a central hospital in the Kingdom of Bahrain. Using the modified CI-based IQSC and a Likert scale (0 to 4), three radiologists assessed the IQ of each examination. AQDs were then established as the median value of and DLP for images with an average score of 3 and compared to national diagnostic reference levels (NDRLs).
Results:
Out of 581 examinations, 60 were excluded from the study due to average scores above or below 3. The established AQDs were lower than the NDRLs for all CIs, except for oncologic follow-up for large patients (28 versus 26 mGy) in scanner A, besides abdominal pain for medium patients (16 versus 15 mGy) and large patients (34 versus 27 mGy), and diverticulitis/appendicitis for medium patients (15 versus 12 mGy) and large patients (33 versus 30 mGy) in scanner B, indicating the need for optimization.
Conclusions:
CI-based IQSC is crucial for IQ assessment and establishing AQDs according to patient size. It identifies stations requiring optimization of patient radiation exposure.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET