The Validity of Apple Watch Series 9 and Ultra 2 for Serial Measurements of Heart Rate Variability and Resting Heart
Ben O'Grady1,2, Rory Lambe1,2, Maximus Baldwin1,2,3
1School of Public Health, Physiotherapy and Sports Science, University College Dublin, D04V1W8 Dublin, Ireland.
Abstract:
The widespread use of wearable devices has enabled continuous monitoring of biometric data, including heart rate variability (HRV) and resting heart rate (RHR). However, the validity of these measurements, particularly from consumer devices like Apple Watch, remains underexplored. This study aimed to validate HRV measurements obtained from Apple Watch Series 9 and Ultra 2 against the Polar H10 chest strap paired with the Kubios HRV software, which together served as the reference standard. A prospective cohort of 39 healthy adults provided 316 HRV measurements over a 14-day period. Generalized Estimating Equations were used to assess the difference in HRV between devices, accounting for repeated measures. Apple Watch tended to underestimate HRV by an average of 8.31 ms compared to the Polar H10 (p = 0.025), with a mean absolute percentage error (MAPE) of 28.88% and a mean absolute error (MAE) of 20.46 ms. The study found no significant impact of RHR discrepancies on HRV differences (p = 0.156), with RHR showing a mean difference of -0.08 bpm, an MAPE of 5.91%, and an MAE of 3.73 bpm. Equivalence testing indicated that the HRV measurements from Apple Watch did not fall within the pre-specified equivalence margin of ±10 ms. Despite accurate RHR measurements, these findings underscore the need for improved HRV algorithms in consumer wearables and caution in interpreting HRV data for clinical or performance monitoring.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...