A bulk Schottky junction for high-sensitivity portable radiation detectors
Yihan Zhang1,2,3, Zongming Huang1,2,3, Chenchen Peng1,2,3
1Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui, 230026, China.
Abstract:
The thickness of X-ray detectors needs to reach hundreds of micrometers to absorb X-ray, and therefore, high voltages over tens or hundreds of volts should be applied to extract X-ray-generated carriers. Here, we propose a bulk Schottky junction for X-ray detection using interpenetrated macroporous-carbon electrodes and metal-halide perovskite networks. The X-ray-generated holes are extracted by the macroporous-carbon electrodes under the built-in electric field, while the electrons in the perovskite phase result in a high gain effect. A high sensitivity of 1.42×105 μC Gyair-1 cm-2 and a low detection limit of 48 nGyair s-1 at a low voltage of -1 V are achieved. We fabricated a dry battery-powered portable X-ray alarm prototype. The pixel detector shows a decent stability under X-ray exposure, and a spatial resolution of up to 5.0 lp mm-1, and the detector arrays also exhibit remarkable uniformity, demonstrating its potential application in X-ray imaging.
More Related Videos
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
05:56Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
Related Concept Videos
Schottky Barrier Diode
Metal-Semiconductor Junctions
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors