Related Experiment Video
Updated: May 8, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
The Protection of RC Columns by Bio-Inspired Honeycomb Column Thin-Walled Structure (BHTS) Under Impact Load
Shijie Wang1, Hongxiang Xia2,3, Yuncui Zong4
1College of Civil and Architectural Engineering, Heilongjiang Institute of Technology, Harbin 150050, China.
Abstract:
The bio-inspired honeycomb column thin-walled structure (BHTS) is inspired by the biological structure of beetle elytra and designed as a lightweight buffer interlayer to prevent damage to the reinforced concrete bridge pier (RCBP) under the overload impact from vehicle impact. According to the prototype structure of the pier, a batch of scale models with a scaling factor of 1:10 was produced. The BHTS buffer interlayer was installed on the reinforced concrete (RC) column specimen to carry out the steel ball impact test. Then, the modified numerical model was subjected to the low-energy input impact test of the steel ball without energy loss during the falling process at the equivalent height of 1.0-3.5 m, and the dynamic response characteristics of the RC column were analyzed. By comparing the impact force and impact duration, maximum displacement, and residual displacement in the impact model, the BHTS buffer interlayer's protective effect on RC columns under lower energy lateral impact was evaluated. Later, a high-energy input lateral impact test of a steel ball falling at an equivalent height of 20.0 m was carried out. According to the material damage, dynamic response, and energy absorption characteristics in the impact model, the failure process of the RC columns was analyzed. The results showed that BHTS absorbed 82.33% of the impact kinetic energy and reduced 77.27% of the impact force, 86.51% of the inertia force, and 64.86% of the base shear force under the failure mode of a 20 m impact condition. It can transform the shear failure of the RC column into bending failure and play an effective protective role for the RC column. This study can provide useful references for collision prevention design in practical engineering.
Related Concept Videos
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Effects of Creep
Reinforcements in Concrete
Fiber Reinforced Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Design of Columns under an Eccentric Load