Related Experiment Video
Updated: May 28, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Comparison of approaches for assessing detection and quantitation limits in bioanalytical methods using HPLC for
Lamia Zaari Lambarki1, Fayssal Jhilal2, Lamia Slimani3
1Applied Organic Chemistry Laboratory, Faculty of Sciences and Technology-Fès, Sidi Mohamed Ben Abdallah University, Fez, Morocco.
Abstract:
The limit of detection (LOD) and limit of quantification (LOQ) stand elements in the validation of analytical and bioanalytical methods as emphasized in numerous guidelines. Despite this, the absence of a universal protocol for establishing these limits has led to varied approaches among researchers and analysts in literature. In this work we present the latest graphical strategy of validation known as the uncertainty profile to assess the LOQ and LOD. Then, we conducted a comparative study of this approach with those based on accuracy profile and parameters of the calibration curve. We realize the uncertainty profile from the uncertainty parameter calculated from the tolerance interval. Furthermore, we provide a succinct overview of alternative methods for computing these limits. This includes the classical strategy based on statistical concepts and graphical one using the method of accuracy profile. In pursuit of this objective, these strategies are implemented in the same experimental results of an HPLC method dedicated for the determination of sotalol in plasma using atenolol as internal standard. The classical strategy based on statistical concepts provides underestimated values of LOD and LOQ. In the other side, the two graphical tools give a relevant and realistic assessment, and the values LOD and LOQ found by uncertainty and accuracy profiles are in the same order of magnitude, especially the method of uncertainty profile. It provides precise estimate of the measurement uncertainty. The graphical strategies of validation, uncertainty profile and accuracy profile, based on tolerance interval are a reliable alternative to the classic strategy, based on classical concepts, for assessment of LOD and LOQ.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
09:04Comprehensive Evaluation of the Effectiveness and Safety of Placenta-Targeted Drug Delivery Using Three Complementary Methods
Published on: September 10, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Elution Process