[When HbA1c fails]
Mads Bisgaard Bengtsen1,2, Esben Søndergaard1
1Steno Diabetes Center Aarhus, Aarhus Universitetshospital.
Recognize potential HbA1c measurement errors. Vigilance is key for discrepancies between continuous glucose monitoring (CGM) and venous HbA1c, especially for managing type 2 diabetes in primary care.
Area of Science:
- Clinical Chemistry
- Endocrinology
- Diabetes Management
Background:
- Continuous glucose monitoring (CGM) is increasingly used for diabetes management.
- Accurate HbA1c measurements are crucial for assessing long-term glycemic control.
- Discrepancies between CGM-estimated HbA1c and laboratory values can impact clinical decisions.
Purpose of the Study:
- To highlight potential pitfalls in HbA1c measurement.
- To emphasize the importance of vigilance regarding discrepancies between CGM-estimated HbA1c and venous HbA1c.
- To inform physicians managing diabetes, particularly in primary care settings.
Main Methods:
- Case report.
- Comparison of HbA1c values derived from continuous glucose monitoring (CGM) and traditional venous blood draws.
- Analysis of potential sources of measurement error.
Main Results:
- Potential for significant discrepancies between CGM-estimated HbA1c and laboratory-measured HbA1c.
- Identification of factors contributing to measurement errors.
- Clinical relevance of these discrepancies in diabetes management.
Conclusions:
- Physicians must be aware of and vigilant for HbA1c measurement errors.
- Discrepancies necessitate careful interpretation of glycemic control data.
- Proactive identification and management of measurement errors are essential for optimal patient care, especially with rising CGM adoption.
More Related Videos
07:22Glycemic Impact on Knee Osteoarthritis Symptoms on Physical, Radiographic, and Inflammatory Markers among Individuals Aged 50 and Over with Diabetes
Published on: March 7, 2025
07:24A Precision Medicine Tool for Measurement and Monitoring of Hemoglobin S in Sickle Cell Disease Patients Receiving Transfusion Therapy
Related Concept Videos
Diabetes: Symptoms, Diagnosis, and Complications
Diabetes Mellitus: Type 2 and Gestational
Hypoglycemia and Glucagon
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...
Carbohydrate Metabolism
Starch accounts for approximately 60% of the carbohydrates consumed by humans. Since amylase enzymes cannot function in the stomach's acidic environment, starch can only be digested in the mouth and small intestine. Simple sugars are found naturally in milk and fruits in...