Related Experiment Video
Updated: Sep 16, 2025

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Palpation versus Ultrasound-Guided Dynamic Needle Tip Positioning Technique for Radial Artery Cannulation
Sujan Dhakal1,2,3, Gentle S Shrestha4,5, Ritesh Lamsal2
1Department of Anaesthesiology and Critical Care, Provincial Hospital Bhadrapur (PHB), Nepal.
The ultrasound-guided dynamic needle tip positioning (USG-DNTP) technique significantly improves first-pass success rates for radial artery cannulation compared to the conventional palpation method. This advanced technique also reduces procedure time and the number of attempts needed.
Area of Science:
- Anesthesiology
- Medical Imaging
- Surgical Procedures
Background:
- Invasive blood pressure monitoring is crucial for perioperative patient management.
- Radial artery cannulation is the standard method, but conventional palpation (CP) can be challenging.
- Alternative techniques are needed to improve cannulation success rates.
Purpose of the Study:
- To compare the first-pass success rate of ultrasound-guided dynamic needle tip positioning (USG-DNTP) with the conventional palpation (CP) method for radial artery cannulation.
- To evaluate secondary outcomes including 5-minute success rate, cannulation time, and number of punctures/cannulae used.
Main Methods:
- A randomized study involving 52 adult patients requiring radial artery cannulation.
- Patients were assigned to either the CP method or the USG-DNTP method.
- Statistical analyses included Chi-square, independent sample t-test, and Mann-Whitney U tests.
Main Results:
- The USG-DNTP method demonstrated a significantly higher first-pass success rate (88.5%) compared to CP (46.2%) (P<0.001).
- Overall 5-minute success rates were 96.2% for USG-DNTP versus 65.4% for CP (P<0.005).
- USG-DNTP required less time (median 44s vs 134s) and fewer skin punctures (1.15 vs 2.04) than CP.
Conclusions:
- The USG-guided DNTP technique significantly enhances the first-pass success rate of radial artery cannulation.
- This method offers improved efficiency and reduced complications compared to the conventional palpation technique.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)