Related Experiment Video
Updated: Sep 16, 2025

Controlled Synthesis and Fluorescence Tracking of Highly Uniform PolyN-isopropylacrylamide Microgels
Published on: September 8, 2016
Predicting the retention time of microparticles in electrokinetic migration
Alaleh Vaghef-Koodehi1, Victor H Perez-Gonzalez2, Blanca H Lapizco-Encinas1
1Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York, 14623, USA. bhlbme@rit.edu.
None:
Insulator based electrokinetic (iEK) devices have emerged as powerful tools for analyzing both nano- and microparticles due to their simplicity, robustness, and ability to integrate linear and nonlinear electrokinetic (EK) effects into a single platform. Recent studies emphasize the importance of nonlinear electrophoresis (EPNL) in particle analysis, for performing separations based on size, shape, and charge differences. Despite these advancements, the development of an empirical equation for predicting particle retention times in iEK-based systems that incorporates EPNL remains limited. This study presents a method for predicting particle retention time in iEK systems in scenarios where the linear EK regime allows for particles migration, while also incorporating EPNL and accounting for particle characteristics, applied electric fields, and microdevice features. Experiments were conducted using eight reference microparticles, grouped into four pairs with similar sizes (3.6 μm to 11.7 μm) but distinct zeta potentials (∼-20 mV and ∼-30 mV), across three distinct iEK microdevices: one with asymmetrical oval-diamond posts, one with symmetrical oval posts, and one postless design. Experimental retention times (tR,e) were measured at applied voltages ranging from 400 V to 1450 V. Using the collected tR,e data, three empirical equations were developed to describe particle velocity, incorporating both linear and nonlinear velocities. Validation with two control particles demonstrated prediction errors below 24% in all devices. These findings underscore the potential of the empirical equations in predicting particle behavior in iEK systems.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Analyte Adsorption and Distribution
Capillary Electrophoresis: Instrumentation