Design and validation of a multi-angle planar surface electrode system for electrical impedance tomography
Busra Oguzhan1, Mustafa Istanbullu2
1Department of Electrical and Electronics Engineering, Kahramanmaras Sutcu Imam University, Kahramanmaras, Turkey.
Abstract:
Electrical impedance-based imaging techniques offer a noninvasive and radiation-free alternative for assessing internal tissue structures. In this study, a novel bioimpedance measurement (BIM) system featuring a planar concentric ring electrode configuration was proposed to improve the spatial resolution and practicality of traditional electrical impedance tomography (EIT) approaches. Inspired by the 360° scanning principle of computed tomography (CT), the system enables multiangle current injection and voltage measurement through a structured stimulation protocol. A total of 32 electrodes, arranged in four concentric rings, were used to capture impedance variations across different angular perspectives, enhancing the detection of localized anomalies. The system was validated through both simulation and experimental studies. Simulations conducted using the EIDORS environment demonstrated successful localization of inhomogeneities within a modeled medium, whereas experimental tests using a saline-filled tank and embedded objects confirmed the system's practical effectiveness. Data acquired from the system were reconstructed into impedance images via the Gauss-Newton algorithm with total variation regularization, followed by image processing steps for improved visualization and boundary identification. The proposed system combines a cost-effective hardware design with a robust measurement and image reconstruction framework, offering a portable and accurate solution for biomedical diagnostics and laboratory research. The results highlight its potential for clinical and nonclinical applications requiring noninvasive monitoring.
Related Concept Videos
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
The Electrical Double Layer
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...