Related Experiment Video
Updated: May 5, 2026

Evaluation of a Smartphone-based Human Activity Recognition System in a Daily Living Environment
Published on: December 11, 2015
Performance evaluation of algorithms to estimate daily sedentary time using wrist-worn sensors in free-living adults
Charles E Matthews1, Pedro Saint-Maurice2, Joshua R Freeman1
1Metabolic Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, MD, USA.
Purpose:
Given the limited real-world testing of algorithms for wrist-worn sensors to estimate sedentary time, we examined the performance of 21 algorithms in free-living adults.
Methods:
Seventy-one adults (35-65 years) wore a GENEActiv (wrist) and an activPAL (thigh) sensor for up to 10 days. activPAL was our reference measure. We estimated sedentary time (hours/day) using 21 classification algorithms, including cut point and machine-learning methods. Valid days from each monitor were matched by date and mean values were calculated. Equivalence testing (±10%) and linear regression were used to compare each algorithm's estimate to the reference, over all participants and by sex and age.
Results:
activPAL recorded a mean of 9.4 hours/d sedentary. Five of 21 algorithms (24%) estimated sedentary time within 10% (±0.94 hours) of the reference. Two of these methods employed machine-learning algorithms (Trost Extended, OxWearables) and three employed cut points (GGIR ENMO 40mg; Bakrania ENMO 32.6mg; Fraysse ENMOa 62.5mg). Variance explained in linear regression was relatively high for the machine-learning (R2=0.44-0.63) and cut point algorithms developed for younger (R2=0.30-0.64) and older (R2=0.45-0.66) adults. More accurate performance was noted for algorithms developed in studies using posture-based ground truth measures and conducted in free-living settings.
Conclusion:
Fifteen of 21 (71%) algorithms produced estimates of sedentary time that were moderate-strongly correlated with the reference measure, but only five (24%) were within 10% of the reference. Free-living benchmarking studies like this can identify more accurate and precise algorithms to estimate sedentary time and identify characteristics of algorithm development studies that yield better results.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure
Holter Monitor: 24-Hour Monitoring