Validation of a Manual Method for Measuring Left Atrial Reservoir Strain Against Automated Speckle Tracking Analysis
Marina Leitman1,2, Vladimir Tyomkin1
1Department of Cardiology, Shamir Medical Center, Zerifin 70300, Israel.
A new manual method for calculating left atrial reservoir strain shows strong agreement with automated software. This technique offers a reliable alternative for assessing cardiac function, especially where automated tools are unavailable.
Area of Science:
- Cardiology
- Medical Imaging
- Echocardiography
Background:
- Left atrial reservoir strain is a key indicator of cardiac function and cardiovascular risk.
- Automated analysis of left atrial strain is not widely accessible, particularly in resource-limited settings.
Purpose of the Study:
- To develop and validate a manual method for biplane left atrial reservoir strain calculation.
- To assess the agreement between manual and automated methods in patients with and without atrial fibrillation.
Main Methods:
- Echocardiography data from 60 patients (30 with atrial fibrillation, 30 in sinus rhythm) were analyzed.
- Left atrial reservoir strain was measured using both automated speckle tracking and a manual point-by-point method.
- Agreement was evaluated using Pearson correlation, Bland-Altman analysis, and intraclass correlation coefficient.
Main Results:
- Strong correlation (r=0.95 in AF, r=0.94 in SR) and excellent agreement were found between manual and automated methods.
- Bland-Altman analysis revealed narrow limits of agreement.
- High intraclass correlation coefficients (0.95 in AF, 0.92 in SR) indicated excellent reliability.
Conclusions:
- Manual measurement of left atrial reservoir strain is feasible and reproducible.
- The manual method demonstrates excellent agreement with automated software.
- This manual approach provides a reliable alternative for left atrial strain assessment when automated tools are unavailable.
More Related Videos
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.