Related Concept Videos

π Electron Effects on Chemical Shift: Overview01:27

π Electron Effects on Chemical Shift: Overview

An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0, resulting in...
Extraction: Effects of pH00:53

Extraction: Effects of pH

Consider a neutral form of an amine, B, with a partition coefficient, K, in a liquid mixture containing organic and aqueous phases. The pH of the aqueous phase affects the charge on acidic and basic solutes, and the charged form is usually more soluble in the aqueous phase. Suppose the conjugate acid form of the amine is soluble only in the aqueous phase while the base form is soluble in both phases. Then the distribution coefficient, D, can be given as the ratio of amine concentration in the...
Tissue Homogenization and Cell Lysis01:32

Tissue Homogenization and Cell Lysis

Tissue homogenization involves disintegrating tissue architecture and lysing cells, and is an early step in isolating and analyzing cellular components. The method used for homogenization depends on the sample type, the amount of sample available, the analyte to be obtained, and the sensitivity of the method. These methods are broadly classified as mechanical and non-mechanical methods.
Mechanical methods of tissue homogenization
These methods rely on applying external physical force to disrupt...
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Precipitate Formation and Particle Size Control01:16

Precipitate Formation and Particle Size Control

In precipitation gravimetry, the precipitating agent should react specifically or selectively with the analyte. While a specific reagent reacts with the analyte alone, a selective reagent can react with a limited number of chemical species.
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Patch Clamp01:18

Patch Clamp

Many fundamental cell functions such as muscle contraction and nerve transmission rely on the electrical signals produced by the movement of positively and negatively charged ions across the cell membrane. One competent method to record current flowing across the whole cell or single ion channel is the patch-clamp technique.
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...