Related Experiment Video
Updated: Jan 17, 2026

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Two-Year Visual, Refractive, and Anatomical Outcomes of Sutureless, Intrascleral, 1-Piece Intraocular Lens Fixation:
Paola Marolo1, Guglielmo Parisi1, Fabio Conte1
1Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy.
Sutureless intrascleral fixation of a single-piece foldable intraocular lens (IOL) provides sustained visual improvement and refractive accuracy over two years. This technique is well-tolerated for secondary implantation in eyes lacking capsular support.
Area of Science:
- Ophthalmology
- Surgical Innovation
- Medical Device Technology
Background:
- Secondary intraocular lens (IOL) implantation is necessary in eyes lacking adequate capsular support.
- Sutureless intrascleral fixation offers a potentially safer alternative to traditional fixation methods.
- Evaluating long-term outcomes of novel IOL designs is crucial for clinical adoption.
Purpose of the Study:
- To assess the 2-year visual, refractive, and anatomical outcomes of a specific foldable single-piece intraocular lens (IOL).
- The IOL is designed for sutureless intrascleral fixation in eyes without sufficient capsular support.
- This study aims to validate the efficacy and safety of this technique for secondary IOL implantation.
Main Methods:
- A prospective, observational, multicenter study was conducted involving 234 eyes of 232 patients.
- A standardized sutureless intrascleral fixation technique using a scleral flap was employed for all IOL implantations.
- Key outcomes including best-corrected visual acuity (BCVA), refractive error, and endothelial cell density (ECD) were monitored over 24 months.
Main Results:
- Mean BCVA significantly improved from 0.74 to 0.26 logMAR (P < 0.001) at 24 months.
- Refractive prediction error within ±1.00 D was achieved in 77% of eyes, with stable outcomes.
- No significant changes in IOL tilt, decentration, or ECD were observed, and complication rates were low.
Conclusions:
- Sutureless intrascleral fixation of this single-piece foldable IOL yields sustained visual gains and high refractive accuracy.
- The technique demonstrates stable anatomical positioning and a favorable safety profile over 24 months.
- This method is well-tolerated and effective for secondary IOL implantation in eyes with compromised capsular support.
More Related Videos
05:56Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model
Published on: April 3, 2016
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment