Related Experiment Video
Updated: Jan 16, 2026

A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Wearable Technology in Diving: A Review of Heart Rate and Oxygen Saturation Monitoring for Enhanced Safety and
Tae Sung Park1,2, Min-Gyu Kim3, Jong-Hwan Park1,4,5
1Department of Convergence Medical Institute of Technology, Pusan National University Hospital, Busan 49241, Republic of Korea.
Abstract:
Monitoring heart rate (HR) and peripheral oxygen saturation (SpO2) in underwater environments has gained increasing importance due to the expanding popularity of diving activities such as SCUBA diving, freediving, and professional underwater operations. These physiological parameters are critical indicators for detecting adaptive responses and early signs of physiological distress caused by environmental stressors like elevated ambient pressure, hypoxia, cold temperatures, and psychological stress. Although recent advances in wearable sensor technologies offer new opportunities for real-time physiological monitoring underwater, significant limitations persist due to issues such as signal interference, cold-induced vasoconstriction, sensor durability, and the complexity of reliably measuring these parameters in dynamic underwater conditions. Evidence shows HR can fall by more than 50% in freedivers and SpO2 may decline to below 50% during repeated dives, with proposed depth-specific thresholds (e.g., <98.5% at 30 m) serving as early warning levels. This review synthesizes current knowledge on the cardiovascular and oxygenation responses observed during diving, explores the technological challenges associated with underwater HR and SpO2 monitoring, and discusses future directions, including the integration of multisensor platforms and predictive analytics to enhance diver safety and physiological monitoring capabilities. Addressing these technological and methodological gaps holds the potential to substantially improve safety standards and expand the clinical applicability of underwater physiological monitoring systems.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

