Related Experiment Video
Updated: Jan 16, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Role of Interatrial Septal Adipose Tissue Volume and Attenuation in Predicting Atrial Tachyarrhythmias Recurrence
Shinichi Tachibana1, Osamu Inaba1, Yukihiro Inamura1
1Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan.
Background:
Left atrial epicardial adipose tissue (LA-EAT) is associated with atrial tachyarrhythmia (AF/AT) recurrence following atrial fibrillation (AF) ablation, of which we recently reported interatrial septal adipose tissue (IAS-AT) has a higher predictive value. This study evaluated the predictive value of IAS-AT volume/attenuation for AF/AT recurrence and compared it with that of other LA-EAT segments.
Methods:
Preoperative multidetector computed tomography (CT) was performed on 350 consecutive patients undergoing initial AF ablation. LA-EAT was defined as tissue with CT attenuation between -190 and -30 Hounsfield units (HU), and IAS-AT was specifically measured in the atrial septum.
Results:
AF/AT recurrence occurred in 71 patients (20.3%) during a mean follow-up of 408 ± 142 days. The mean IAS-AT volume was 1.8 ± 1.5 mL, and attenuation was -69.3 ± 8.9 HU. IAS-AT volume (≥ 1.7 mL; hazard ratio [HR] 2.12, 95% confidence interval [CI] 1.26-3.56, p = 0.004) and attenuation (≤-66.7 HU; HR 2.31, 95% CI 1.25-4.26, p = 0.007) were independent predictors of AF/AT recurrence. Receiver operating characteristic analyses revealed that the predictive value of IAS-AT attenuation was comparable to that of LA-EAT attenuation other than IAS-AT (area under the curve (AUC), 0.611 vs. 0.602; p = 0.815). However, IAS-AT volume was superior to LA-EAT volume other than IAS-AT in predicting recurrent AF/AT (AUC, 0.67 vs. 0.58; p = 0.001).
Conclusion:
IAS-AT volume and attenuation are significant predictors of AF/AT recurrence, with IAS-AT volume providing an enhanced predictive value compared to other LA-EAT segment volumes. IAS-AT may be an indicator of AF/AT recurrence after AF ablation.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019