Applying a vacuum ultraviolet detector for liquid chromatography: Simultaneous analysis of four organic acids and
Mayur Bansal1, Annika Dombrowski2, Chinoso Nwanebi3
1Interdisciplinary Life Sciences Graduate Program, The University of Texas at Austin, 2500 Speedway Avenue, Austin, TX 78712, United States.
Abstract:
The initial application of a prototype vacuum ultraviolet (VUV) absorption detector system for high performance liquid chromatography (HPLC) was validated and characterized. This detector enabled simultaneous detection and quantification of four organic acids-lactic, acetic, itaconic, and citric along with four carbohydrates-glucose, fructose, galactose, and lactose. This collection of analytes was selected based on their prevalence in fermentations, metabolic production interest, and occurrence in food processes/chemistry. Full spectrum VUV data, collected across 7 discrete wavelength bands centered at 177.3, 190.3, 203.1, 215.8, 228.3, 240.7, and 252.9 nm, yielded unique fingerprints that allowed for separation and quantification of strongly co-eluting peaks, most notably the hexose sugars. Separations were performed on an Aminex HPX-87H ion exclusion column using 5 mM H₂SO₄ as the isocratic mobile phase at 0.6 mL/min, with samples preheated to 40 °C. Across the eight analytes, Hydra limits of detection spanned 0.0228-3.59 g/L, with calibration linearity of R2 = 0.941-0.998. The VUV prototype maintained linear response up to 100 g/L for all analytes (60 g/L for itaconic acid), whereas refractive index detection saturated between ∼10-60 g/L depending on the analyte. Spectral deconvolution recovered co-eluting organic acids with ∼1-4% error and the co-eluting hexose cluster within ∼11-19% error, demonstrating practical spectral selectivity for overlapped peaks. This extended dynamic range can eliminate the need for sample dilution thus greatly streamlining workflow processes and minimizing the dilution of trace components. The combination of quantitative accuracy and spectral selectivity was demonstrated though the monitoring of glucose utilization and lactic acid production during a seven-day Saccharomyces cerevisiae fermentation with minimal sample preparation. These results support the potential of LC-VUV detection as a robust, high-throughput method for metabolite analysis in high titer bioprocessing applications. However, a current limitation of the prototype is reduced sensitivity at low concentrations relative to conventional detectors, indicating that present performance is best suited to higher titer samples.
More Related Videos
11:06GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
Published on: May 19, 2012
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...