Related Experiment Video
Updated: Jan 29, 2026

Applying Dynamic Strain on Thin Oxide Films Immobilized on a Pseudoelastic Nickel-Titanium Alloy
Published on: July 28, 2020
Effect of Clockwise Reciprocation Motion of Optimum Torque Reverse Kinematic on the Cyclic Fatigue Resistance of
Jorge N R Martins1,2,3,4, Emmanuel J N L Silva5,6,7, Duarte Marques1,2,3,4
1Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal.
Abstract:
This study evaluated the effect of clockwise reciprocation motion used in the original Optimum Torque Reverse kinematics, compared with clockwise continuous rotation, on the cyclic fatigue strength of nickel-titanium rotary instruments (NiTi) with different metallurgical characteristics. A total of 120 instruments, ProFile and EndoSequence in sizes 25/.04, 30/.04, and 35/.04, were tested under continuous rotation or reciprocation motions (n = 10 per subgroup). Instruments were examined by optical and scanning electron microscopy to exclude manufacturing defects. Phase transformation temperatures were determined by differential scanning calorimetry, and cyclic fatigue testing was conducted using a custom device simulating a curved canal with a 6 mm radius and an 86° curvature. The time to fracture was recorded, and the number of cycles to fracture was calculated. Statistical comparisons were performed using the Mann-Whitney U test with a significance level of p < 0.05. Differential scanning calorimetry showed that ProFile instruments were fully austenitic at the test temperature, while EndoSequence instruments exhibited a mixed R-phase and austenitic structure. Clockwise reciprocation motion significantly increased cyclic fatigue resistance in all groups compared with clockwise continuous rotation. Time to fracture increased by 241.3% to 337.5%, and EndoSequence instruments consistently demonstrated higher fatigue resistance. The greatest relative improvement was observed in ProFile 35/.04, with a 422.4% increase in the number of cycles to fracture. Overall, the reciprocation motion markedly enhanced cyclic fatigue strength irrespective of metallurgical phase composition, indicating a practical mechanical benefit that may reduce the risk of instrument separation during endodontic procedures.
More Related Videos
Related Concept Videos
Torque Free Motion
Torque
Torque can be considered as the rotational counterpart to force. Since forces change the translational...
Net Torque Calculations
Fatigue
Kinematic Equations - I
Factors Influencing Attraction IV: Reciprocity

