Related Experiment Video
Updated: Feb 4, 2026

Studying Chronic Exposure of Mice to Ultraviolet B Radiation
Published on: August 19, 2025
Single-Center, Open-Label, Randomized Controlled Trial on the Reduction of Scattered Radiation Exposure to the
Shodhan R Aithal1, Hermohander Singh Isser, Zubair Farooq
1Department of Cardiology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi.
Radiation protection drapes significantly reduce operator radiation exposure during catheterization procedures. Pectoral access poses the highest risk, but drapes offer substantial protection across all vascular access sites.
Area of Science:
- Interventional Cardiology
- Radiation Safety
- Occupational Health
Background:
- Catheterization laboratory procedures expose primary operators to significant occupational radiation hazards.
- Vascular access sites (radial, femoral, pectoral) influence scattered radiation levels for operators.
- Minimizing radiation exposure is crucial for the long-term health of interventional cardiologists.
Purpose of the Study:
- To evaluate scattered radiation exposure to the primary operator at different vascular access sites.
- To assess the effectiveness of radiation protection drapes in reducing operator radiation dose.
- To compare radiation exposure across radial, femoral, and pectoral vascular access during catheterization.
Main Methods:
- A single-center, randomized controlled trial involving 216 patients undergoing catheterization.
- Patients were randomized to standard radiation protection or additional shielding with radiation protection drapes.
- Operator radiation dose was measured and normalized to air kerma (AK), dose area product (DAP), and cine-adjusted screen time (CAST).
Main Results:
- Pectoral access resulted in the highest operator radiation exposure (96.75 µSv) compared to femoral (45.72 µSv) and radial (49.06 µSv) access.
- Radiation protection drapes significantly reduced operator exposure across all access sites (P < 0.05).
- Reductions in exposure with drapes ranged from 48% to 82% depending on the access site and radiation parameter measured.
Conclusions:
- Radiation protection drapes are highly effective in minimizing primary operator radiation exposure during catheterization.
- Pectoral vascular access requires particular attention due to higher associated radiation doses.
- Routine use of radiation protection drapes is recommended to enhance safety for interventional cardiology staff.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
11:24Measuring DNA Damage and Repair in Mouse Splenocytes After Chronic In Vivo Exposure to Very Low Doses of Beta- and Gamma-Radiation
Published on: July 3, 2015
Related Concept Videos
Biological Effects of Radiation
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Radiation: Applications
The average...
Absorption of Radiation
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Generating Electromagnetic Radiations