Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
A wearable 3D-printed hollow microneedle device for pressure-driven interstitial fluid collection and testing
Nedim Hacıosmanoğlu1,2, Emre Ece1,2, Fatih Inci1,2
1UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey. finci@bilkent.edu.tr.
None:
Interstitial fluid (ISF) is the extracellular fluid within the dermis that transports biomolecules diffusing from blood vessels to lymphatic vessels. Owing to its blood-like composition and accessibility only a few millimeters beneath the skin surface, ISF has recently attracted considerable attention as a minimally invasive reservoir for biomarker analysis. Conventional ISF collection relies on invasive sampling methods. Microneedle (MN) technology has emerged as a promising approach for developing minimally invasive ISF sampling and analysis systems. We present a design and one-step stereolithography (SLA)-based 3D printing fabrication of a wearable hollow MN device: μHolloSense. The device is capable of negative pressure-assisted ISF collection via its syringe port and is compatible with lateral flow assay (LFA) testing through a dedicated test port. The overall cost was ∼$1 per single-use device, including all components, and $1.50 per SARS-CoV-2 antigen test, used here as a proof-of-concept LFA system. Additionally, a 3D-printed, agarose-based skin-mimicking platform was developed to provide a standardized tool for evaluating MN sampling performance. Beyond this model system, ex vivo skin experiments were conducted to validate the applicability of μHolloSense for ISF collection in biologically relevant tissues. Our results demonstrate that μHolloSense, featuring a refined tip diameter (44.19 ± 2.4 μm) and height (1207.93 ± 11.25 μm), is capable of drawing liquids at a rate sufficient to reach the dermis, exhibiting robust mechanical properties (>0.17 N compressive force per needle) in IgG LFA tests across antigen concentrations of 1, 10, 100, and 250 pg mL-1. Ex vivo experiments on mice skin confirmed ISF extraction of up to 6 μL per sampling, with protein concentrations consistent with physiological levels. Collectively, this work presents a unified strategy for the design, fabrication, and evaluation of 3D-printed hollow MN systems with an integrated negative-pressure approach for ISF-based biomolecule analysis. In the future, further optimization and clinical validation of this platform would enable continuous, minimally invasive monitoring of a wide range of biomarkers, paving the way for point-of-care diagnostic and personalized health applications.
Related Concept Videos
Pressure of Fluids
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Vapor Pressure of Fluid
When a liquid is placed in a closed container with a small air space, and the space is evacuated, vapor molecules will...
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...
Fluid Pressure over Flat Plate of Constant Width
The resultant force...