Direct Detection of Isolevuglandins in Tissues Using a D11 scFv-Alkaline Phosphatase Fusion Protein and Immunofluorescence
Published on: July 5, 2021
A dual-mode biosensor for alkaline phosphatase detection based on DCIP and Eu3+-calcein
Bingyu Fu1,2,3, Yanru Shao1, Zhixiong Zheng1
1College of Life Science, Yangtze University, Jingzhou, Hubei, 434025, China. xuqi@yangtzeu.edu.cn.
This study introduces a dual-mode biosensor for detecting alkaline phosphatase (ALP). The biosensor utilizes colorimetric and fluorescent signals, offering sensitive and selective detection of ALP in samples.
Area of Science:
- Biomedical Engineering
- Analytical Chemistry
- Biochemistry
Background:
- Alkaline phosphatase (ALP) is a crucial enzyme involved in various physiological and pathological processes.
- Accurate detection of ALP is essential for diagnosing diseases like liver disorders and bone diseases.
- Existing biosensors often lack sensitivity, selectivity, or dual-mode detection capabilities.
Purpose of the Study:
- To develop a simple and sensitive dual-mode biosensor for alkaline phosphatase (ALP) detection.
- To leverage both colorimetric and fluorescent signals for enhanced detection accuracy.
- To validate the biosensor's performance in complex biological matrices like serum samples.
Main Methods:
- Designed a dual-mode biosensor utilizing 2,6-dichloroindiphenol (DCIP) colorimetry and calcein fluorescence.
- Employed L-ascorbic acid-2-phosphate (AAP) as a substrate, which is dephosphorylated by ALP into ascorbic acid (AA) and phosphate ions.
- Utilized the reducing property of AA to decolorize DCIP and the chelating ability of phosphate ions to restore Eu3+-calcein fluorescence.
Main Results:
- Colorimetric mode: Linear detection range of 1.56-50 U L-1, Limit of Detection (LOD) of 0.27 U L-1.
- Fluorescence mode: Linear detection range of 0.78-25 U L-1, LOD of 0.23 U L-1.
- Demonstrated excellent selectivity for ALP and satisfactory recovery rates in serum samples.
Conclusions:
- The developed dual-mode biosensor offers a simple, sensitive, and selective method for ALP detection.
- The combined colorimetric and fluorescent approach enhances detection reliability.
- This biosensor shows potential for clinical diagnostics and biochemical analysis.
Related Concept Videos
Protein Kinases and Phosphatases
Protein kinases
Many proteins in the cell are regulated by phosphorylation, the addition of a phosphate group. A family of enzymes called kinases...
Protein Kinases and Phosphatases
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Modes of Standing Waves - I
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....