Related Experiment Video
Updated: Jul 1, 2026

08:30
X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
The hard X-ray ptychography endstation at the Taiwan Photon Source
Yi Wei Tsai1, Gung Chian Yin1, Bo Yi Chen1
1National Synchrotron Radiation Research Center, Hsinchu 300, Taiwan.
Journal of Synchrotron Radiation
|March 20, 2026
Summary
The upgraded Taiwan Photon Source (TPS) 25A2 endstation now offers advanced hard X-ray 2D ptychography. This powerful nanoscale imaging tool achieves sub-10 nm resolution, enabling detailed studies of nanoparticles and biological structures.
Area of Science:
- Materials Science
- Physics
- Biotechnology
Background:
- Ptychography is an advanced imaging technique utilizing overlapping diffraction patterns.
- The Taiwan Photon Source (TPS) previously demonstrated ptychography capabilities.
- Further system upgrades were necessary to enhance resolution and performance.
Purpose of the Study:
- To detail the design and performance of the upgraded hard X-ray 2D ptychography endstation, TPS 25A2.
- To establish a new benchmark for nanoscale imaging resolution at TPS.
- To showcase the endstation's capabilities for diverse scientific applications.
Main Methods:
- Integration of a zone-plate focusing system into the existing Kirkpatrick-Baez mirror optics.
- Operation at a photon energy of 8.979 keV.
- Characterization using a Siemens star test pattern for resolution assessment.
Main Results:
- Routine achievement of sub-10 nm spatial resolution in 2D imaging.
- Highest recorded resolution of 6.9 nm on a Siemens star test pattern.
- Successful imaging of inorganic nanoparticles and a complex biological structure.
Conclusions:
- The upgraded TPS 25A2 endstation provides a powerful and accessible tool for nanoscale imaging.
- The system demonstrates state-of-the-art resolution for hard X-ray ptychography.
- This advancement significantly benefits the scientific community for advanced materials and biological research.
More Related Videos
Related Concept Videos
X-ray Imaging
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Positron Emission Tomography
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Fundamental Principles of PET

