From Fixed-Frequency to Tunable: Advances in Acoustic Sensors for Physiological Acoustic Monitoring
Jiantao Wang1,2, Chuting Liu1,2, Peiyan Dong1,2
1School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, No. 66, Gongchang Road, Guangming District, Shenzhen 518107, China.
Abstract:
Continuous, non-invasive cardiopulmonary monitoring is receiving increasing attention as population aging and chronic diseases rise. Acoustic sensing provides diagnostically relevant information with relatively simple hardware. Yet, physiological body sounds span heterogeneous and partially overlapping spectra and are highly susceptible to environmental noise and motion artifacts, which limit conventional stethoscopes and fixed-frequency sensors. Frequency-Tunable Acoustic Sensors (FTAS) offer a promising route toward frequency-selective amplification and adaptive interference suppression by matching their resonance to target signals, thereby potentially supporting multi-site monitoring and personalized diagnostics on a single platform. This review starts with an overview of physiological sound generation and the evolution of auscultation, then surveys mainstream medical acoustic transducers (piezoelectric, capacitive microelectromechanical systems (MEMS), piezoresistive and triboelectric) and their limitations in frequency selectivity. Resonance-tuning strategies are classified into three paradigms: electrical tuning, material-based tuning, and geometric reconfiguration, and their tuning ranges, response characteristics, and representative implementations are comparatively discussed. Finally, this review discusses the potential translational value of FTAS in physiological acoustic signal monitoring, particularly in cardiovascular and respiratory assessment, and emphasizes the remaining challenges, including the trade-off between sensitivity and selectivity, as well as long-term biocompatibility. At the same time, this review highlights their development prospects in customizable acoustic sensing platforms.
More Related Videos
15:25Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
Published on: February 4, 2018
10:50Behavioral Determination of Stimulus Pair Discrimination of Auditory Acoustic and Electrical Stimuli Using a Classical Conditioning and Heart-rate Approach
Published on: June 6, 2012
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...