Impact of Baydur ratio correction on the reliability of esophageal pressure measurement
Andrea Restivo1,2, Michele Delle Vergini1,2, Genevieve McCormack1
1Anesthesia Center for Critical Care Research, Department of Anaesthesiology, Critical Care and Pain Medicine, Mass General Brigham and Harvard Medical School, Boston, Massachusetts, United States.
Abstract:
Tidal changes in esophageal pressure (ΔPes) are used as a surrogate for pleural pressure changes (ΔPpl) to assess chest wall mechanics. The Baydur ratio evaluates pressure transmission and guides catheter positioning. The effects of correcting ΔPes using the Baydur ratio on the accuracy of ΔPpl estimation and its dependence on ventilation mode, spontaneous inspiratory effort, and body position remain unclear. In 10 pigs, ΔPpl was measured using intrapleural balloon catheters, whereas Pes was recorded at three esophageal locations in supine and prone positions. Animals underwent controlled and assisted ventilation. Baydur ratios were derived during assisted ventilation and from external chest compressions during controlled ventilation. ΔPes before and after correction was compared with ΔPpl using mixed-effects models and Bland-Altman analysis. In addition, we quantified the proportion of values with (ΔPes - ΔPpl) ≤ 1 cmH2O. During assisted ventilation, ΔPes showed good agreement with posterior ΔPpl. Baydur correction improved scaling and association (slope: 0.76 vs. 0.50; r = 0.81 vs. 0.79, P < 0.01) and increased values within ±1 cmH2O from 29% to 45% when the Baydur ratio fell outside the accepted range. During controlled ventilation, ΔPes showed weaker association and wider limits of agreement, without improvement after correction. Similar patterns were observed in the prone position. ΔPes more accurately reflected posterior ΔPpl during assisted ventilation. Baydur correction improves scaling and association, particularly when the Baydur ratio falls outside the accepted range, but does not improve and may worsen agreement during controlled ventilation.NEW & NOTEWORTHY This study shows that the reliability of esophageal pressure as a surrogate of pleural pressure depends on ventilation mode. Using a minimally invasive approach for direct pleural pressure measurement with balloon catheters, we found that Baydur ratio correction improves ΔPes accuracy during assisted ventilation, particularly when the ratio falls outside the accepted range, but not during controlled ventilation.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement