Related Experiment Video
Updated: Aug 13, 2026

Automatic Laser-based Geometry Capture for Finite Element Analysis of Weld Beads
Published on: July 25, 2025
An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam
Fenghua Weng1, Gaoyu Chen2, Yunlong Zan2
1Faculty of Applied Sciences, Macao Polytechnic University, Macao 999078, People's Republic of China.
Abstract:
Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

