Detection of nitro-polycyclic aromatic hydrocarbons in liquid chromatography by zinc reduction and peroxyoxalate
Abstract:
Detection limits in the range 0.25-8.5 pg have been obtained for nitro-polycyclic aromatic hydrocarbons (nitro-PAHs) in high-performance liquid chromatography (HPLC). The nitro-PAHs are reduced on-line to the corresponding amino-PAHs and detected by peroxyoxalate chemiluminescence. Quantitative reduction is achieved on a short (3.5 X 0.32 cm) column packed with a 1:1 mixture of glass beads (ca. 40 micron) and zinc particles (40-80 micron). The mobile phase consists of 70-80% acetonitrile, the balance being a 50-mM tris(hydroxymethyl)aminomethane hydrochloride (pH 6.5) buffer, which is necessary both for the reduction and for catalysis of the chemiluminescent reaction. The amino-PAHs are excited by energy transfer from the decomposition products of the reaction between hydrogen peroxide and bis(2,4,6-trichlorophenyl)oxalate. These reagents are introduced by post-column mixing, and the emission is detected by means of a conventional fluorescence detector with its light source turned off. We reported the high sensitivity and selectivity of peroxyoxalate chemiluminescence toward amino-PAHs in earlier work. The method yields a linear response over at least three orders of magnitude, and in most cases the detection limits are better than those obtained by fluorescence detection with the same fluorometer. The reduction column may be placed either before or after the analytical column, so that the analytes are eluted either as the nitro-PAHs or the corresponding amino-PAHs. This feature provides a second characteristic retention time and is useful in identifying the detected compounds. The technique has been applied to the selective detection of nitro-PAHs in carbon black. The carbon black samples were Soxhlet extracted with toluene, evaporated to dryness, and the extracts redissolved in methylene chloride for direct injection into the HPLC column. The principal compounds found in the carbon black samples were poly-substituted nitro-PAHs and unsubstituted PAHs. This method provides a sensitive and selective method for the analysis of complex samples for these environmentally important mutagens.
More Related Videos
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors