Related Experiment Videos
Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials
A D Liou1, J I Nicholls, R A Yuodelis
1Department of Restorative Dentistry, University of Washington, Seattle 98195.
The International Journal of Prosthodontics
|July 1, 1993
Summary
Dental impression copings from Steri-Oss and Dental Imaging Associates showed higher accuracy when reseated compared to Implant Innovations. No significant difference was found between Impregum F and Extrude impression materials.
Area of Science:
- Dental Materials Science
- Prosthodontics
- Implant Dentistry
Background:
- Accurate transfer coping replacement is crucial for successful dental implant restorations.
- Variability in impression materials and coping designs may affect replacement accuracy.
Purpose of the Study:
- To evaluate the accuracy of reseating tapered transfer copings from three different manufacturers into two elastomeric impression materials.
- To compare the replacement accuracy among Dental Imaging Associates, Implant Innovations Inc., and Steri-Oss copings.
Main Methods:
- Five operators repeatedly replaced copings from Dental Imaging Associates, Implant Innovations Inc., and Steri-Oss into impressions made with Impregum F and Extrude.
- Angular deviations (replacement error) were measured between the original and replaced coping positions.
- Statistical analysis was performed to compare accuracy between coping manufacturers and impression materials.
Main Results:
- No single coping could be replaced accurately and consistently by all operators.
- Steri-Oss and Dental Imaging Associates copings demonstrated significantly lower angular deviations (higher accuracy) compared to the Implant Innovations coping.
- No significant difference in replacement accuracy was observed between Impregum F and Extrude impression materials.
Conclusions:
- The manufacturer of the tapered transfer coping significantly influences its replacement accuracy in dental impressions.
- Steri-Oss and Dental Imaging Associates copings offer superior reseating accuracy over Implant Innovations copings.
- Impression material choice (Impregum F vs. Extrude) does not significantly impact the accuracy of these specific coping replacements.