Related Experiment Video
Updated: Aug 11, 2026

Investigations on the Ga(III) Complex of EOB-DTPA and Its 68Ga Radiolabeled Analogue
Published on: August 17, 2016
Hepatobiliary scanning using 99mTc-pyridoxylideneglutamate
Abstract:
Technetium 99m-pyridoxylideneglutamate (99mTc-PG) administered intravenously is excreted by hepatocytes into the bile canaliculi and enters the gallbladder through the cystic duct and consequently, can be used for scanning the hepatobiliary ductal system. A total of 166 patients representing 27 normal subjects, 84 patients referred for investigation for pain in the upper right quadrant of the abdomen and 55 jaundiced patients were evaluated with 99mTc-PG. In normal human volunteers, the agent reached the liver in five minutes, and the common bile duct, gallbladder, and duodenum within 15 minutes. Satisfactory images of the hepatobiliary tract were obtained using small dosages of 99mTc-PG. The gallbladder was not visualized when the cystic duct was occluded. In the presence of acute cholecystitis, cystic duct obstruction, or in chronic cholecystitis where other roentgenographic studies showd a nonfunctioning gallbladder, there was no concentration of 99mTc-PG in the gallbladder. In partial common bile duct obstruction is distended common bile duct was visualized along with delay in transit of radioactivity into the duodenum. Complete common bile duct obstruction was associatedwith no radioactivity in either the biliary or the gastrointestinal tracts up to 24 hours after injection. Hepatocellular disease was characterized by delayed liver clearance and delayed visualization of biliary and gastrointestinal tracts. 99mTc-PG scanning proved capable of differentiating between hepatocellular disease and extrahepatic biliary tract obstruction.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

