Related Experiment Video
Updated: Aug 15, 2026

Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
Thick-film electrochemical immunosensor based on stripping potentiometric detection of a metal ion label
1Department of Chemistry and Biochemistry, New Mexico State University, Las Cruces 88003, USA.
Abstract:
A disposable electrochemical immunosensor based on potentiometric stripping analysis (PSA) of a metal tracer and using an entirely on-chip assay format is demonstrated. Challenges associated with the adaptation of earlier stripping voltammetric immunoassays to an on-chip operation, and with meeting the demands of decentralized testing, have been addressed. These include the surface immobilization of the antibody, the replacement of mercury drop electrodes, elimination of the separation and oxygen-removal steps, and the use of quiescent 30-microL sample droplets. Human serum albumin (HSA) and anti-HSA antibody were used as a model system, while bismuth ion served as the metal label. The anti-HSA was immobilized onto the surface of a thick-film electrode, followed by a competition between the Bi-labeled analyte-tracer and the analyte (HSA) for the antibody binding sites. Upon removal of the unbound tracer, Bi3+ was released and detected by PSA. The dynamic concentration range for HSA (0.3-30 micrograms/mL) and the detection limit (0.2 microgram/mL, i.e., 90 fmol in the 30-microL sample) indicate that the greatly simplified protocol does not compromise the performance characteristics of stripping immunoassays. Consequently, this on-chip operation offers great promise for decentralized (clinical and environmental) applications.
More Related Videos
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
08:22Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
Related Concept Videos
Potentiometry: Overview
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Membrane Electrodes
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...