Neonatal total parenteral nutrition ascites from liver erosion by umbilical vein catheters
B D Coley1, J Seguin, L Cordero
1Department of Radiology, Children's Radiological Institute and Columbus Children's Hospital, 700 Children's Drive, Columbus, OH 43205, USA.
Background:
A preterm infant was found to have total parenteral nutrition (TPN) ascites after infusion through a low umbilical vein catheter (UVC). Objective. To evaluate the clinical and imaging findings of neonates with TPN ascites after infusion through UVCs.
Materials And Methods:
Eight patients with TPN ascites were identified over three years. Charts were abstracted for clinical data. Plain-film, ultrasound (US), and contrast studies through the UVCs were examined to determine UVC placement, presence of liver injury, and confirmation of intraperitoneal extravasation from the UVC.
Results:
All eight patients with TPN ascites presented with hypotension and abdominal distension. All had UVCs overlying the liver on plain film. Catheters were in place a mean of 8.9 days prior to TPN extravasation. US in four patients showed hepatic parenchymal damage around the UVC tip. Contrast studies in six patients showed intraperitoneal spill.
Conclusion:
While low UVC placement may sometimes be clinically unavoidable, TPN administered through abnormally positioned UVCs is not without risk.