Related Experiment Video
Updated: Aug 23, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Results of heart valve replacement with the SORIN prosthesis
T Colombo1, F Donatelli, E Quaini
1Divisione di Cardiochirurgia A. de Gasperis Ente Ospedaliero Niguarda-Ca' Granda, Milan, Italy.
Abstract:
From March 1977 to December 1981, 872 patients at our institution underwent valve replacement with a pyrolytic carbon tilting disc prosthesis manufactured in Italy by SORIN-Biomedica. To verify the performance characteristics of this prosthesis, we analyzed the intermediate-term results obtained over a cumulative total of 3,041 patient-years (pt-yr) of follow-up. Three hundred sixty-nine patients underwent mitral valve replacement (MVR), 309 had aortic valve replacement (AVR), and 194 had both mitral and aortic (double) valve replacement (DVR). Expressed in actuarial terms (% [+/- standard error of the mean] free of adverse events at 5 years) and in linearized terms (% pt-yr), respectively, valve-related complications occurred at the following rates: Thromboembolism, 89.9 +/- 1.9% and 2.1 +/- 0.4% pt-yr (MVR); 92.1 +/- 1.9% and 1.7 +/- 0.4% (AVR); 90.5 +/- 5.0% and 2.2 +/- 0.6% (DVR). Anticoagulant-related hemorrhage, 95.2 +/- 1.5% and 1.4 +/- 0.3% (MVR); 95.9 +/- 1.5% and 1.3 +/- 0.3% (AVR); 96.0 +/- 2.0% and 0.9 +/- 0.4% (DVR). Prosthetic valve endocarditis, 99.0 +/- 0.6% and 0.2 +/- 0.1% (MVR); 97.4 +/- 1.0% and 0.6 +/- 0.2% (AVR); 94.5 +/- 1.7% and 1.4 +/- 0.4% (DVR). Reoperation, 92.6 +/- 1.5% and 1.7 +/- 0.3% (MVR); 89.4 +/- 1.9% and 2.4 +/- 0.4% (AVR); 82.3 +/- 2.9% and 4.8 +/- 0.8% (DVR). The total valve-related morbidity and mortality was 79.6 +/- 2.6% and 4.9 +/- 0.6% (MVR); 79.7 +/- 2.6% and 5.1 +/- 0.6% (AVR); 70.5 +/- 4.0% and 7.7 +/- 1.1% (DVR). The 5-year actuarial survival rate without hospital mortality was 86.8 +/- 2.0% (MVR), 91.0 +/- 1.7% (AVR), and 78.8 +/- 3.7% (DVR). The intermediate-term survival and complication rates showed the performance of the SORIN prosthesis to be quite satisfactory.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Stenosis III: Medical Management
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse I: Introduction
Mitral Regurgitation I: Introduction

