Flip angle calculation for consistent contrast in spoiled gradient echo imaging.

Reed F Busse1

  • 1GE Healthcare, Applied Science Lab, 333 Ravenswood Ave, Building 307, Menlo Park, California, USA. reed.busse@med.ge.com

Magnetic Resonance in Medicine
|March 31, 2005
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Optimizing isotropic three-dimensional fast spin-echo methods for imaging the knee.

Journal of magnetic resonance imaging : JMRI·2014
Same author

Three-dimensional brain MRI for DBS patients within ultra-low radiofrequency power limits.

Movement disorders : official journal of the Movement Disorder Society·2014
Same author

High resolution navigated three-dimensional T₁-weighted hepatobiliary MRI using gadoxetic acid optimized for 1.5 Tesla.

Journal of magnetic resonance imaging : JMRI·2012
Same author

Improved motion correction capabilities for fast spin echo T1 FLAIR propeller using non-cartesian external calibration data driven parallel imaging.

Magnetic resonance in medicine·2012
Same author

Optimized double inversion recovery for reduction of T₁ weighting in fluid-attenuated inversion recovery.

Magnetic resonance in medicine·2011
Same author

Brain MR imaging at ultra-low radiofrequency power.

Radiology·2011
Same journal

Multi-Contrast Human Brain CEST MRI at 11.7 T: First In Vivo Demonstration.

Magnetic resonance in medicine·2026
Same journal

Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging.

Magnetic resonance in medicine·2026
Same journal

A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp-Logan.

Magnetic resonance in medicine·2026
Same journal

7T 3D-EPI PCASL With High SNR Efficiency and Robustness to Through-Plane B<sub>0</sub> Field Gradients.

Magnetic resonance in medicine·2026
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
See all related articles

Researchers developed a method to maintain consistent T(1)-weighting in spoiled gradient echo MRI sequences. This technique allows for stable image contrast across varying repetition times (TR), improving reproducibility and comparison of MRI studies.

Area of Science:

  • Magnetic Resonance Imaging (MRI)
  • Biomedical Engineering
  • Medical Physics

Background:

  • T(1)-weighting in spoiled gradient echo sequences is sensitive to repetition time (TR) and flip angle (alpha).
  • Inconsistent TR variations can compromise contrast-to-noise optimization and reproducibility.
  • Current methods lack direct comparison of contrast properties across different TRs.

Purpose of the Study:

  • To demonstrate a method for maintaining consistent relative contrast in spoiled gradient echo sequences.
  • To enable comparison and reproduction of T(1)-weighted contrast across varying TR values.
  • To allow TR flexibility without sacrificing contrast consistency.

Main Methods:

  • Calculating and automatically adjusting the flip angle (alpha) to compensate for TR variations.

Related Experiment Videos

  • Ensuring the signal-versus-T(1) curve shape (relative contrast) remains consistent.
  • Demonstrating proportional signal scaling with the square root of TR.
  • Main Results:

    • Achieved consistent relative contrast across different TRs by adjusting alpha.
    • Showed that signal intensity scales proportionally to radicalTR in all tissues.
    • Established a method for comparing and reproducing T(1)-weighting across sequences with different TRs.

    Conclusions:

    • Consistent T(1)-weighting and relative contrast can be maintained in spoiled gradient echo sequences.
    • The developed method allows TR to vary for sequence parameter accommodation without impacting contrast.
    • This approach enhances the comparability and reproducibility of MRI studies.