Anion binding vs. deprotonation in colorimetric pyrrolylamidothiourea based anion sensors

Louise S Evans1, Philip A Gale, Mark E Light

  • 1School of Chemistry, University of Southampton, Southampton SO17 1BJ, UK.

Chemical Communications (Cambridge, England)
|February 24, 2006
PubMed

Related Concept Videos

EDTA: Indirect and Alkalimetric Titration01:23

EDTA: Indirect and Alkalimetric Titration

Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
EDTA: Auxiliary Complexing Reagents01:26

EDTA: Auxiliary Complexing Reagents

EDTA titrations are usually carried out in highly basic conditions, where the fully deprotonated form of EDTA, Y4−, actively complexes with the free metal ions in the solution. Several metal ions precipitate as hydrous oxide (hydroxides, oxides, or oxyhydroxides) under these conditions, lowering the concentration of free metal ions in the solution. For this reason, auxiliary complexing agents or ligands such as ammonia, tartrate, citrate, or triethanolamine are used in EDTA titrations to...
Basicity of Heterocyclic Aromatic Amines01:25

Basicity of Heterocyclic Aromatic Amines

Heterocyclic amines, where the N atom is a part of an alicyclic system, are similar in basicity to alkylamines. Interestingly, the heterocyclic amine having a nitrogen atom as part of an aromatic ring has much less basicity than its corresponding alicyclic counterpart. For this reason, as presented in Figure 1, piperidine (pKb = 2.8) is significantly more basic than pyridine (pKb = 8.8).
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Titration of Polyprotic Acids with a Strong Base01:23

Titration of Polyprotic Acids with a Strong Base

Titration of a polyprotic acid, which contains multiple ionizable protons, involves distinct dissociation steps, each with its own dissociation constant (Ka). Each successive Ka is weaker than the previous one. In the titration of a polyprotic acid like sulfurous acid with a strong base such as sodium hydroxide, the base first neutralizes the initial ionizable proton, forming an intermediate species (e.g., hydrogen sulfite ions). This step's titration curve resembles that of a weak monoprotic...