Determination of chlorpyrifos and its metabolites in rat brain tissue using coupled-column liquid chromatography/electrospray ionization tandem mass spectrometry
Related Experiment Video
Updated: Aug 6, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Leah N Williamson1, Alvin V Terry, Michael G Bartlett
1Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, USA.
Abstract:
A method has been developed to quantify chlorpyrifos (O,O-diethyl-O-[3,5,6,-trichloro-2-pyridyl] phosphorothionate) and its metabolites chlorpyrifos-oxon (O,O-diethyl-O-[3,5,6,trichloro-2-pyridinyl] phosphate) and TCP (3,5,6,-trichloro-2-pyridinol) in rat brain tissue by coupled-column liquid chromatography/electrospray ionization tandem mass spectrometry (LC/LC/ESI-MS/MS). Rat brains were homogenized and treated by protein precipitation using ice-cold acetonitrile. The supernatant was directly injected onto the coupled-column system. Sample clean-up was achieved on a Zorbax Extend-C(18) column (2.1 x 50 mm, 5 microm) using a mobile phase of acetonitrile/water with 0.0025% formic acid (40:60, v/v). The compounds were separated isocratically on a Zorbax Eclipse XDB C(8) column (2.0 x 150 mm, 5 microm) using a mobile phase of acetonitrile/water with 0.0025% formic acid (75:25, v/v). Chlorpyrifos and chlorpyrifos-oxon were detected in positive ion mode using multiple reaction monitoring (MRM). TCP was detected in negative ion mode using precursor-to-precursor transition monitoring. The method was validated and the specificity, linearity, limit of quantitation (LOQ), precision, accuracy, stability, and recoveries were determined. Calibration curves for all three analytes yielded correlation coefficients of 0.993 or greater. The LOQs were 25.3 ng/g for chlorpyrifos and 6.3 ng/g for chlorpyrifos-oxon and TCP. All precision relative standard deviations (RSDs) were less than 16% for the LOQ and less than 11% for the other QC samples. This method was successfully applied to six rats that were injected subcutaneously with chlorpyrifos.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
09:01Metabolomic Analysis of Rat Brain by High Resolution Nuclear Magnetic Resonance Spectroscopy of Tissue Extracts
Published on: September 21, 2014