Introduction:
Troponin levels have been demonstrated to predict mortality in patients with cardiomyopathy. Implantable cardiac defibrillator (ICD) devices have been demonstrated to improve survival. It is not clear if ICDs would mitigate the negative outcome predicted by elevated troponin levels.
Methods:
We collected baseline blood samples for troponin T (TnT) and creatinine kinase-MB fraction in consecutive patients immediately before successful pectoral transvenous ICD implant. Patients were followed for total mortality. For analysis, patients were grouped by TnT detectability (>or=0.01 ng/mL).
Results:
Fifty-two men, aged 68 +/- 10 years, were studied. Mean ejection fraction was 29 +/- 12% and 65% had ischemic cardiomyopathy. Follow-up duration was 17 +/- 8 months. None of the patients had abnormal creatinine kinase-MB fraction levels (1.7 +/- 1.1 ng/mL). There were 37 patients with no detectable TnT (Group I) and 15 with detectable TnT (Group II). There was no difference between the two groups in terms of age (68 vs 69, P = NS), ejection fraction (30 vs 29%, P = NS), or proportion of patients with ischemic cardiomyopathy (68 vs 60%, P = NS). During follow-up 16 (31%) patients died. Patients in group I had mortality of 16% (6/37) compared to 67% mortality (10/15, P < 0.001) in group II. On multivariate analysis, detectable TnT remained an independent predictor of mortality (HR 4.5, CI 1.4-14.25, P = 0.01).
Conclusion:
In a cohort of patients with cardiomyopathy undergoing ICD implantation for standard clinical indications, presence of detectable TnT was associated with high mortality despite ICD implantation. TnT obtained before ICD implantation may be useful for risk stratification.
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Cardiomyopathy II: Dilated Cardiomyopathy
Dysrhythmias V: Evaluating Dysrhythmias
Cardiomyopathy V: Interprofessional Care